Google Cloud Status Dashboard
This page provides status information on the services that are part of Google Cloud Platform. Check back here to view the current status of the services listed below. If you are experiencing an issue not listed here, please contact Support. Learn more about what's posted on the dashboard in this FAQ. For additional information on these services, please visit cloud.google.com.
Google Compute Engine Incident #20009
We are experiencing an issue with Google Compute Engine instances running RHEL and CentOS 7 and 8. Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart.
Incident began at 2020-07-30 08:38 and ended at 2020-07-30 13:17 (all times are US/Pacific).
| Date | Time | Description | |
|---|---|---|---|
| Jul 30, 2020 | 13:17 | The issue with Google Compute Engine instances running RHEL and CentOS 7 and 8 is being actively investigated by Redhat. More details on this issue are available in the following article and bugs:
Please follow our public issue tracker posting (https://issuetracker.google.com/162523000) for updates on this issue going forward. No further updates will be provided here. |
|
The issue with Google Compute Engine instances running RHEL and CentOS 7 and 8 is being actively investigated by Redhat. More details on this issue are available in the following article and bugs:
Please follow our public issue tracker posting (https://issuetracker.google.com/162523000) for updates on this issue going forward. No further updates will be provided here. |
|||
| Jul 30, 2020 | 10:52 | Description: We are experiencing an issue with Google Compute Engine instances running RHEL and CentOS 7 and 8. More details on this issue are available in the following article and bugs: https://access.redhat.com/solutions/5272311 Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run We will provide an update by Thursday, 2020-07-30 14:00 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run |
|
Description: We are experiencing an issue with Google Compute Engine instances running RHEL and CentOS 7 and 8. More details on this issue are available in the following article and bugs: https://access.redhat.com/solutions/5272311 Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run We will provide an update by Thursday, 2020-07-30 14:00 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run |
|||
| Jul 30, 2020 | 09:52 | Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 11:00 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run |
|
Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 11:00 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: Affected shim versions: CentOS 7: shim-x64-15-7.el7_9.x86_64 Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run |
|||
| Jul 30, 2020 | 09:41 | Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 10:30 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: rpm -q shim-x64 Affected shim versions: Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run "yum downgrade shim* grub2* mokutil" to downgrade to the correct version. This command may not work on CentOS 8. If you have already rebooted, you will need to attach the disk to another instance, chroot into the disk, then run the yum downgrade command. |
|
Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 10:30 US/Pacific with current details. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart with errors messages referring to a combination of: "X64 Exception Type - 0D(#GP - General Protection) CPU Apic ID", "FXSAVE_STATE" or "Find image based on IP". This issue affects instances with specific versions of the shim package installed. To find the currently installed shim version, use the following command: rpm -q shim-x64 Affected shim versions: Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. If you are on an affected shim version, run "yum downgrade shim* grub2* mokutil" to downgrade to the correct version. This command may not work on CentOS 8. If you have already rebooted, you will need to attach the disk to another instance, chroot into the disk, then run the yum downgrade command. |
|||
| Jul 30, 2020 | 09:27 | Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We are also preparing instructions for recovery from this issue for affected instances. We will provide an update by Thursday, 2020-07-30 10:15 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. |
|
Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We are also preparing instructions for recovery from this issue for affected instances. We will provide an update by Thursday, 2020-07-30 10:15 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. |
|||
| Jul 30, 2020 | 08:49 | Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 09:30 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. |
|
Description: We are experiencing an issue with Google Compute Engine RHEL and CentOS 7 and 8 instances. Symptoms: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Customers should not update or reboot instances running RHEL or CentOS 7 and 8. Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-07-30 09:30 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Instances running RHEL and CentOS 7 and 8 that run yum update may fail to boot after restart. Workaround: Do not update or reboot instances running RHEL or CentOS 7 and 8. |
|||