This page provides status information on the services that are part of Google Cloud. Check back here to view the current status of the services listed below. If you are experiencing an issue not listed here, please contact Support. Learn more about what's posted on the dashboard in this FAQ. For additional information on these services, please visit https://cloud.google.com/.

For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.

  • Available
  • Service information
  • Service disruption
  • Service outage

Incident affecting Google Cloud Networking, Google Compute Engine, Cloud Spanner, Google Cloud Pub/Sub, Hybrid Connectivity

We've been informed that Cloud Networking, and Load Balancer, are not functioning in europe-west2

Incident began at 2021-08-06 01:56 and ended at 2021-08-06 05:41 (all times are US/Pacific).

Date Time Description
6 Aug 2021 11:56 PDT

We apologize for the inconvenience this service disruption/outage may have caused. We would like to provide some information about this incident below. Please note, this information is based on our best knowledge at the time of posting and is subject to change as our investigation continues. If you have experienced impact outside of what is listed below, please reach out to Google Support by opening a case using https://cloud.google.com/support

(All Times US/Pacific)

Incident Timeline:

06 August 2021 01:56 - 03:23

06 August 2021 05:27 - 05:41

Duration: 1 hours, 41 minutes

Affected Services and Features:

Google Cloud Networking, Cloud Load Balancing, Compute Engine, Cloud Spanner, Pub/Sub, Cloud Interconnect

Regions/Zones: europe-west2-a

Description:

Google Cloud Networking and Google Cloud Load Balancing (GCLB) experienced elevated packet loss in europe-west2-a. From preliminary analysis, the root cause of the issue is a configuration change on a device that caused a permission issue with an automatic configuration deployment and failed to propagate. This resulted in a corrupted configuration which caused traffic to be dropped.

Customer Impact:

Customers experienced elevated packet loss or connection terminations for connections in europe-west2-a. A small number of Compute Engine instances failed to start in europe-west2-a. Cloud Interconnect in europe-west2 observed an increase in packet loss. Cloud Spanner requests passing through europe-west2-a experienced increased error rates. Cloud Pub/Sub may have experienced increased error rates when publishing to topics in europe-west2-a.

6 Aug 2021 04:31 PDT

The issue with Cloud Networking / Load Balancing has been resolved for all affected users as of Friday, 2021-08-06 03:22 US/Pacific.

We thank you for your patience while we worked on resolving the issue.

6 Aug 2021 03:59 PDT

Summary: We've been informed that Cloud Networking, and Load Balancer, are not functioning in europe-west2

Description: Mitigation work is currently underway by our engineering team.

We do not have an ETA for mitigation at this point.

We will provide more information by Friday, 2021-08-06 04:36 US/Pacific.

Diagnosis: None at this time.

Workaround: None at this time.

6 Aug 2021 03:00 PDT

Summary: We've been informed that Cloud Networking, and Load Balancer, are not functioning in europe-west2

Description: We are investigating a potential issue with Cloud Networking and/or Load Balancing in europe-west2.

We will provide more information by Friday, 2021-08-06 04:00 US/Pacific.

Diagnosis: None at this time.

Workaround: None at this time.