Service Health
For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.
Incident affecting Google Cloud Functions
Some deployments to Google Cloud Functions using go113 runtime are failing
Incident began at 2020-10-23 06:22 and ended at 2020-10-23 08:00 (all times are US/Pacific).
| Date | Time | Description | |
|---|---|---|---|
| | 23 Oct 2020 | 08:00 PDT | The issue with deployments of Google Cloud Functions using go113 runtime has been resolved for all affected users as of Friday, 2020-10-23 07:51 US/Pacific. We thank you for your patience while we worked on resolving the issue. |
| | 23 Oct 2020 | 07:54 PDT | Description: Mitigation work is currently underway by our engineering team. We do not have an ETA for mitigation at this point. We will provide more information by Friday, 2020-10-23 08:15 US/Pacific. Diagnosis: Customers affected by this issue may see an error similar to the following: ERROR: (gcloud.functions.deploy) OperationError: code=3, message=Build failed: # github.com/cloudevents/sdk-go/v2/extensions src/github.com/cloudevents/sdk-go/v2/extensions/distributed_tracing_extension.go:161:3: cannot use span (type trace.Span) as type *trace.Span in return argument: *trace.Span is pointer to interface, not interface; Error ID: 1093f764 Workaround: Customers can avoid this issue by making sure to include a "go.mod" file in their project. For more information see this blog post: |
| | 23 Oct 2020 | 07:13 PDT | Description: We are experiencing an issue with Google Cloud Functions, affecting deployments using the "go113" runtime, beginning at Thursday, 2020-10-22 15:00 US/Pacific. Our engineering team continues to investigate the issue. We will provide an update by Friday, 2020-10-23 08:00 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Customers affected by this issue may see an error similar to the following: ERROR: (gcloud.functions.deploy) OperationError: code=3, message=Build failed: # github.com/cloudevents/sdk-go/v2/extensions src/github.com/cloudevents/sdk-go/v2/extensions/distributed_tracing_extension.go:161:3: cannot use span (type trace.Span) as type *trace.Span in return argument: *trace.Span is pointer to interface, not interface; Error ID: 1093f764 Workaround: Customers can avoid this issue by making sure to include a "go.mod" file in their project. For more information see this blog post: |
| | 23 Oct 2020 | 06:47 PDT | Description: We are experiencing an issue with Google Cloud Functions, affecting deployments using the "go113" runtime, beginning at Thursday, 2020-10-22 15:00 US/Pacific. Our engineering team continues to investigate the issue. We will provide an update by Friday, 2020-10-23 08:00 US/Pacific with current details. We apologize to all who are affected by the disruption. Diagnosis: Customers affected by this issue may see an error similar to the following: ERROR: (gcloud.functions.deploy) OperationError: code=3, message=Build failed: # github.com/cloudevents/sdk-go/v2/extensions src/github.com/cloudevents/sdk-go/v2/extensions/distributed_tracing_extension.go:161:3: cannot use span (type trace.Span) as type *trace.Span in return argument: *trace.Span is pointer to interface, not interface; Error ID: 1093f764 Workaround: None at this time. |
- All times are US/Pacific