This page provides status information on the services that are part of Google Cloud. Check back here to view the current status of the services listed below. If you are experiencing an issue not listed here, please contact Support. Learn more about what's posted on the dashboard in this FAQ. For additional information on these services, please visit https://cloud.google.com/.

For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.

  • Available
  • Service disruption
  • Service outage

Incident affecting Google Cloud Storage

Google Cloud Storage (GCS) customers experienced elevated latencies and error rates when performing upload or write operations.

Incident began at 2026-10-08 04:00 and ended at 2026-10-09 09:46 (all times are US/Pacific).

Previously affected location(s)

Iowa (us-central1)

Date Time Description
14 Oct 2026 00:15 PDT

Incident Report

Date/Time of the Issue (All time US/Pacific)

Incident First Occurrence

Incident Start: 08 October 2026 04:00

Incident End: 08 October 2026 16:30

Duration: 12 hours, 30 minutes

Incident Recurrence

Recurrence Start: 09 October 2026 04:05

Recurrence End: 09 October 2026 09:46

Duration: 5 hours, 41 minutes

Total Duration: 18 hours, 11 minutes

Summary

On Thursday, 08 October 2026, Google Cloud Storage experienced elevated write latency and write error rates while performing upload or write operations in the us-central1 region for a duration of 12 hours, 30 minutes. This was followed by a recurrence on Friday, 09 October 2026 in the us-central1-b zone for a duration of 5 hours, 41 minutes. We are taking immediate steps to ensure this doesn’t happen again.

Root Cause

Google Cloud Storage relies on a highly distributed backend architecture to process and store incoming data. During the incident window, specific storage backend nodes within the us-central1 region experienced a localized capacity shortfall due to increased traffic.

The sequence of events leading to customer impact was as follows:

  • A traffic sorting optimization configuration update to the Google Cloud Storage load balancing layer intended to address localized capacity constraints caused severe resource exhaustion on specific storage backend nodes in the affected region by inadvertently bypassing the standard capacity-aware routing logic, resulting in a severe load imbalance.
  • Consequently, a small fraction of storage backend nodes in the us-central1 region received an overwhelming proportion of incoming write traffic despite having low available serving capacity. This concentration of traffic led to resource exhaustion on the affected backend servers causing backend services handling object data ingestion to begin timing out.
  • Because the underlying instances could not process the high volume of requests quickly enough, the incoming upload and write requests routed to these nodes experienced elevated latency and failed to complete, resulting in errors surfaced to customers.
  • Concurrently, a separate issue with the underlying database service contributed to additional metadata processing errors during a portion of the incident window.
  • The recurrence of the issue on October 9 was caused by an incomplete rollback of an upload planner feature, which broke the load balancing mechanism and overloaded a few smaller storage backend nodes.

Remediation and Prevention

The issue was initially detected on 08 October 2026 at 04:50 by Google engineering teams actively monitoring system telemetry early in the incident window. 

To mitigate the issue, Google engineers executed the following step-by-step strategy:

  • Engineers initially attempted to dynamically allocate additional emergency capacity to the affected region, but this was blocked by systemic regional capacity limits.
  • To relieve immediate pressure, engineers selectively drained traffic from the most overloaded storage backend nodes.
  • A configuration change was deployed to disable the traffic sorting optimization, significantly reducing resource overhead on the storage backend.
  • For the concurrent metadata issue, engineers rolled back a recent update to the underlying metadata database service.
  • While these steps provided temporary relief, a recurrence of the load imbalance required further traffic redirection and draining of affected storage components. The incident was permanently resolved when engineering fully reverted the problematic load balancing configuration change, restoring the previous capacity-aware routing behavior and allowing traffic to distribute evenly across the region.

Once traffic levels stabilized and resource utilization returned to normal baseline levels, the previously drained nodes were restored to active service, successfully restoring normal operations.

Preventative Actions:

To ensure this issue does not recur, we are implementing the following improvements:

  • Safe Configuration Rollouts: We are updating our deployment protocols to ensure that load balancing logic changes are rigorously validated in alternative, smaller regions before being rolled out to larger, highly utilized regions.
  • Intelligent Operational Controls: We are enhancing the storage load balancing architecture to strictly enforce capacity constraints, ensuring that traffic distribution logic cannot bypass pre-spilling safeguards and route traffic to clusters lacking sufficient serving resources.
  • Resilient Scaling Logic: We are implementing targeted improvements to accelerate internal data movement within highly utilized storage cells, enabling the system to process data more efficiently and handle temporary load spikes with greater resilience.

Description of Impact

On 08 October 2026, from 04:00 to 16:30 in us-central1 region and 09 October 2026, from 04:05 to 09:46 in us-central1-b zone, customers experienced elevated latency and error rates during Cloud Storage upload and write operations.

  • Upload & Write Failures: Customers primarily observed HTTP 503 UNAVAILABLE errors on WriteObject operations and client-side timeouts.
  • Increased Write Latency: Write operations that did succeed experienced significantly higher latencies than normal.
  • Cloud Storage operations in all other regions, as well as all other Google Cloud services, remained unaffected by this specific event.
9 Oct 2026 09:44 PDT

Preliminary Incident Report

We sincerely apologize for the disruption this incident caused to your business. We know how much you rely on Google Cloud, and we regret the impact on your productivity. We are working to address the root cause and prevent this from occurring in the future.

Please note, this information is based on our best knowledge at the time of posting and is subject to change as our investigation continues. A final Incident Report with preventative actions will be posted once our investigation is complete.

If you have experienced impact outside of what is listed below, please reach out to Google Cloud Support using https://cloud.google.com/support

Date/Time of the Issue (All time US/Pacific)

Incident Start: 08 October 2026 04:00

Incident End: 08 October 2026 16:30

Duration: 12 hours, 30 minutes

Summary

On Thursday, 08 October 2026, Google Cloud Storage experienced elevated write latency and write error rates in the us-central1 region for a duration of 12 hours, 30 minutes. We are taking immediate steps to ensure this doesn’t happen again.

Preliminary Root Cause

Google Cloud Storage relies on a highly distributed backend architecture to process and store incoming data. During the incident window, specific storage backend nodes within the us-central1 region experienced a localized capacity shortfall.

The sequence of events leading to customer impact was as follows:

  • A traffic sorting optimization intended to address localized capacity constraints caused severe resource exhaustion on specific backend storage nodes in the affected region.
  • This resource exhaustion caused backend services handling object data ingestion to begin timing out.
  • As a result, incoming upload and write requests routed to these nodes experienced elevated latency and failed to complete, resulting in errors surfaced to customers.
  • Concurrently, a separate issue with the underlying database service contributed to additional metadata processing errors during a portion of the incident window.

Google engineers have begun a full root cause analysis (RCA) and will provide additional information once it is available.

Remediation

The issue was initially detected by Google engineering teams actively monitoring system telemetry early in the incident window.

To mitigate the issue, Google engineers executed the following step-by-step strategy:

  • Engineers initially attempted to dynamically allocate additional emergency capacity to the affected region, but this was blocked by systemic regional capacity limits.
  • To relieve immediate pressure, engineers selectively drained traffic from the most overloaded backend storage nodes.
  • A configuration change was deployed to disable the traffic sorting optimization, significantly reducing resource overhead on the storage backend.
  • For the concurrent metadata issue, engineers rolled back a recent update to the underlying metadata database service.

Once traffic levels stabilized and resource utilization returned to normal baseline levels, the previously drained nodes were restored to active service, successfully restoring normal operations.

Description of Impact

On 08 October, 2026, from 04:00 to 16:30 US/Pacific, customers utilizing the us-central1 region experienced elevated latency and error rates during Cloud Storage upload and write operations.

  • Customers primarily observed HTTP 503 UNAVAILABLE errors on WriteObject operations and client-side timeouts.
  • A minor impact was also observed on read operations during this timeframe.
  • Cloud Storage operations in all other regions, as well as all other Google Cloud services, remained unaffected by this specific event.
8 Oct 2026 13:48 PDT

Summary

Google Cloud Storage customers are experiencing elevated latencies and error rates when performing upload or write operations

Description

We are continuing to mitigate the issue with Google Cloud Storage in the us-central1 region that began on Thursday, 2026-10-08 05:19 PDT.

The initial mitigations applied by our engineering team continue to show observable improvements in error rates.

Our engineering team is actively monitoring the environment and rolling out further mitigations to fully stabilize the service.

We will provide an update by Thursday, 2026-10-08 16:00 PDT with current details.

Customer Symptoms

  • Customers are experiencing elevated latencies and error rates when performing upload or write operations.
  • A smaller subset of read operations may also experience increased latency and errors

Workaround

None at this time.

8 Oct 2026 12:38 PDT

Summary

Google Cloud Storage customers are experiencing elevated latencies and error rates when performing upload or write operations

Description

We are continuing to mitigate the issue with Google Cloud Storage in the us-central1 region that began on Thursday, 2026-10-08 05:19 PDT.

The initial mitigations applied by our engineering team continue to show observable improvements in error rates. Our engineering team is actively monitoring the environment and rolling out further mitigations to fully stabilize the service.

We will provide an update by Thursday, 2026-10-08 14:00 PDT with current details.

Customer Symptoms

  • Customers are experiencing elevated latencies and error rates when performing upload or write operations.
  • A smaller subset of read operations may also experience increased latency and errors

Workaround

None at this time.

8 Oct 2026 11:55 PDT

Summary

Google Cloud Storage customers are experiencing elevated latencies and error rates when performing upload or write operations

Description

We are experiencing an issue with Google Cloud Storage beginning on Thursday, 2026-10-08 05:19 PDT.

Initial mitigations applied by our engineering team leading to observable improvements in error rates in our internal monitoring beginning 10:57 PDT. Work remains underway to roll out further mitigations.

We will provide an update by Thursday, 2026-10-08 12:45 PDT with current details.

Customer Symptoms

  • Customers are experiencing elevated latencies and error rates when performing upload or write operations.
  • A smaller subset of read operations may also experience increased latency and errors

Workaround

None at this time.

8 Oct 2026 11:34 PDT

Summary

Google Cloud Storage customers are experiencing elevated latencies and error rates when performing upload or write operations

Description

We are experiencing an issue with Google Cloud Storage beginning on Thursday, 2026-10-08 05:19 PDT.

Initial mitigations applied by our engineering team leading to observable improvements in error rates in our internal monitoring. Work remains underway to roll out further mitigations.

We will provide an update by Thursday, 2026-10-08 12:00 PDT with current details.

Customer Symptoms

  • Customers are experiencing elevated latencies and error rates when performing upload or write operations.
  • A smaller subset of read operations may also experience increased latency and errors

Workaround

None at this time.

8 Oct 2026 11:24 PDT

Summary

Google Cloud Storage customers are experiencing elevated latencies and error rates when performing upload or write operations

Description

We are experiencing an issue with Google Cloud Storage beginning on Thursday, 2026-10-08 05:19 PDT.

Our engineering team continues to investigate the issue.

We will provide an update by Thursday, 2026-10-08 11:50 PDT with current details.

Customer Symptoms

  • Customers are experiencing elevated latencies and error rates when performing upload or write operations.
  • A smaller subset of read operations may also experience increased latency and errors

Workaround

None at this time.