Incident affecting Google BigQuery
BigQuery S3 Data Transfer Service experiencing issues in us-multiregion, asia-noutheast1 and asia-southeast1
Incident began at 2022-02-21 21:45 and ended at 2022-02-25 12:22 (all times are US/Pacific).
| Date | Time | Description | |
|---|---|---|---|
| | 25 Feb 2022 | 15:20 PST | We apologize for the inconvenience this service disruption/outage may have caused. We would like to provide some information about this incident below. Please note, this information is based on our best knowledge at the time of posting and is subject to change as our investigation continues. If you have experienced impact outside of what is listed below, please reach out to Google Support by opening a case using https://cloud.google.com/support. (All Times US/Pacific) Incident Start: 21 February 2022 21:45 Incident End: 25 February 2022 12:22 Duration: 3 days, 14 hours, 37 minutes Affected Services and Features: Google BigQuery - Data Transfer Service Regions/Zones: Global Description: Google BigQuery S3 Data Transfer Service experienced table validation failures globally, with the majority of impact observed in us-multiregion, asia-northeast1, and asia-southeast1. From preliminary analysis, the root cause of the issue was a rollout that started on 21 February 2022 at 01:00 US/Pacific. A rollback was initiated on 25 February 2022 at 08:29 to mitigate the issue in the most heavily affected regions (us-multiregion, asia-northeast1, and asia-southeast1) which was completed on 25 February 2022 12:01. Customer Impact:
[1] - https://cloud.google.com/bigquery-transfer/docs/s3-transfer-intro [2] - https://cloud.google.com/bigquery-transfer/docs/s3-transfer-parameters Additional Details:
|
| | 25 Feb 2022 | 12:04 PST | The issue with Google BigQuery has been resolved for all affected users as of Friday, 2022-02-25 12:03 US/Pacific. We thank you for your patience while we worked on resolving the issue. |
| | 25 Feb 2022 | 09:57 PST | Summary: BigQuery S3 Data Transfer Service experiencing issues in us-multiregion, asia-noutheast1 and asia-southeast1 Description: Mitigation work is currently underway by our engineering team. The mitigation is expected to complete by the following dates/times: US-Multiregion - Friday, 2022-02-25 12:00 US/Pacific. Asia-southeast1 and Asia-northeast1 - Friday, 2022-02-25 14:00 US/Pacific. Other regions potentially impacted - Tuesday, 2022-03-01 EOB US/Pacific. We will provide more information by Friday, 2022-02-25 12:00 US/Pacific. Diagnosis: S3 transfers may fail table validation when table name contains template argument (e.g., "{run_time}") Workaround: None at this time. |
- All times are US/Pacific