This page provides status information on the services that are part of Google Cloud. Check back here to view the current status of the services listed below. If you are experiencing an issue not listed here, please contact Support. Learn more about what's posted on the dashboard in this FAQ. For additional information on these services, please visit https://cloud.google.com/.

For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.

  • Available
  • Service information
  • Service disruption
  • Service outage

Incident affecting Google Cloud Bigtable

Cloud Monitoring: Missing Bigtable Replication Metrics

Incident began at 2022-12-14 16:47 and ended at 2022-12-14 21:12 (all times are US/Pacific).

Previously affected location(s)

Osaka (asia-northeast2)Melbourne (australia-southeast2)Frankfurt (europe-west3)Milan (europe-west8)Santiago (southamerica-west1)Northern Virginia (us-east4)Las Vegas (us-west4)

Date Time Description
14 Dec 2022 21:12 PST

The issue with Google Cloud Bigtable has been resolved for all affected users as of Wednesday, 2022-12-14 21:00 US/Pacific.

We thank you for your patience while we worked on resolving the issue.

14 Dec 2022 20:33 PST

Summary: Cloud Monitoring: Missing Bigtable Replication Metrics

Description: We are experiencing an issue with Google Cloud Bigtable Metrics. CPU Load Metrics are impacted and could show the CPU Load as zero in the impacted locations. Customers who are periodically scaling their clusters based on the CPU Load Metrics will be operating on wrong data. Customers who are using the Cloud Bigtable native Autoscaling feature are NOT impacted. Replication metrics are also affected.

Our engineering team continues to investigate the issue.

We will provide an update by Wednesday, 2022-12-14 22:00 US/Pacific with current details.

Diagnosis: Customers may be missing data in Cloud Monitoring for the following metrics:

  • bigtable.googleapis.com/cluster/cpu_load,
  • bigtable.googleapis.com/replication/latency,
  • bigtable.googleapis.com/replication/max_delay

Workaround: None at this time.

14 Dec 2022 19:56 PST

Summary: Cloud Monitoring: Missing Bigtable Replication Metrics

Description: We are experiencing an issue with Google Cloud Bigtable Metrics. CPU Load Metrics are impacted and could show the CPU Load as zero in the impacted locations. Customers who are periodically scaling their clusters based on the CPU Load Metrics will be operating on wrong data. Replication metrics are also affected for selected zones.

Our engineering team continues to investigate the issue.

We will provide an update by Wednesday, 2022-12-14 22:00 US/Pacific with current details.

Diagnosis: Customers may be missing data in Cloud Monitoring for the following metrics:

  • bigtable.googleapis.com/cluster/cpu_load,
  • bigtable.googleapis.com/replication/latency,
  • bigtable.googleapis.com/replication/max_delay

Workaround: None at this time.

14 Dec 2022 19:43 PST

Summary: Cloud Monitoring: Missing Bigtable Replication Metrics

Description: We are experiencing an issue with Google Cloud Bigtable Metrics. CPU Load Metrics are impacted and could show the CPU Load as zero in the impacted locations. Customers who are periodically scaling their clusters based on the CPU Load Metrics will be operating on wrong data. Replication metrics are also affected for selected zones.

Our engineering team continues to investigate the issue.

We will provide an update by Wednesday, 2022-12-14 22:00 US/Pacific with current details.

Diagnosis: Customers may be missing data in Cloud Monitoring for the following metrics:

bigtable.googleapis.com/replication/latency bigtable.googleapis.com/replication/max_delay

Workaround: None at this time.