This page provides status information on the services that are part of Google Cloud. Check back here to view the current status of the services listed below. If you are experiencing an issue not listed here, please contact Support. Learn more about what's posted on the dashboard in this FAQ. For additional information on these services, please visit https://cloud.google.com/.

For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.

  • Available
  • Service information
  • Service disruption
  • Service outage

Incident affecting Hybrid Connectivity, Google Cloud Networking

Cloud Router route priorities being wrong

Incident began at 2022-06-21 03:22 and ended at 2022-06-21 08:05 (all times are US/Pacific).

Previously affected location(s)

Taiwan (asia-east1)Hong Kong (asia-east2)Tokyo (asia-northeast1)Osaka (asia-northeast2)Seoul (asia-northeast3)Mumbai (asia-south1)Delhi (asia-south2)Singapore (asia-southeast1)Jakarta (asia-southeast2)Sydney (australia-southeast1)Melbourne (australia-southeast2)Warsaw (europe-central2)Finland (europe-north1)Belgium (europe-west1)London (europe-west2)Frankfurt (europe-west3)Netherlands (europe-west4)Zurich (europe-west6)Montréal (northamerica-northeast1)Toronto (northamerica-northeast2)São Paulo (southamerica-east1)Santiago (southamerica-west1)Iowa (us-central1)South Carolina (us-east1)Northern Virginia (us-east4)Oregon (us-west1)Los Angeles (us-west2)Salt Lake City (us-west3)Las Vegas (us-west4)

Date Time Description
21 Jun 2022 08:05 PDT

The issue with Hybrid Connectivity has been resolved for all affected users as of Tuesday, 2022-06-21 07:45 US/Pacific.

We thank you for your patience while we worked on resolving the issue.

21 Jun 2022 06:48 PDT

Summary: Cloud Router route priorities being wrong

Description: Mitigation work is currently underway by our engineering team.

The mitigation is expected to complete by Tuesday, 2022-06-21 09:00 US/Pacific.

We will provide more information by Tuesday, 2022-06-21 09:00 US/Pacific.

Diagnosis: Route priorities between regions can differ between HA0 and HA1 attachments within GCP and thus traffic might flow in unexpected way

Workaround: Adjust route priorities or shutdown secondary paths

21 Jun 2022 06:00 PDT

Summary: Cloud Router route priorities being wrong

Description: Mitigation work is still underway by our engineering team.

We will provide more information by Tuesday, 2022-06-21 07:00 US/Pacific.

Diagnosis: Route priorities between regions can differ between HA0 and HA1 attachments within GCP and thus traffic might flow in unexpected way

Workaround: Adjust route priorities or shutdown secondary paths

21 Jun 2022 05:21 PDT

Summary: Cloud Router route priorities being wrong

Description: We are experiencing an issue with Hybrid Connectivity beginning at Friday, 2022-06-17 17:15 US/Pacific

Our engineering team continues to investigate the issue.

We will provide an update by Tuesday, 2022-06-21 06:00 US/Pacific with current details.

We apologize to all who are affected by the disruption.

Diagnosis: Route priorities between regions can differ between HA0 and HA1 attachments within GCP and thus traffic might flow in unexpected way

Workaround: Adjust route priorities or shutdown secondary paths