Service Health
For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.
Incident affecting Operations
We are investigating an alerting issue in Stackdriver Monitoring
Incident began at 2020-02-27 15:05 and ended at 2020-02-27 18:06 (all times are US/Pacific).
| Date | Time | Description | |
|---|---|---|---|
| | 27 Feb 2020 | 18:06 PST | The issue with Stackdriver Monitoring has been resolved for all affected users as of Thursday, 2020-02-27 18:01 US/Pacific. We thank you for your patience while we've worked on resolving the issue. |
| | 27 Feb 2020 | 17:36 PST | Description: We are experiencing an issue with Stackdriver Monitoring. Symptoms: Some alerting policies are not being evaluated. Our engineering team continues to investigate the issue. We will provide an update by Thursday, 2020-02-27 18:10 US/Pacific with current details. Diagnosis: Users with alerting policies that aggregate away all resource labels for certain resource types may be affected: gce_instance, gae_app, cloud_tasks_queue, cloudsql_database, gce_disk, vpn_gateway, pubsub_topic, pubsub_subscription, pubsub_snapshot. Workaround: Adding a resource label, for instance project_id, to the Group By fields in the condition will enable the alerting policies to be evaluated. |
| | 27 Feb 2020 | 17:14 PST | Description: We are investigating a potential issue with Stackdriver Monitoring. We will provide more information by Thursday, 2020-02-27 17:45 US/Pacific. |
- All times are US/Pacific