Service Health
For incidents related to Google Security Products, visit https://status.cloud.google.com/security. For incidents related to Looker (original), visit https://status.cloud.google.com/looker.
-
Available -
Service information -
Service disruption -
Service outage
Incident affecting VMWare engine, Google Compute Engine
Google Cloud VMWare engine is experiencing network link issues
Incident began at 2023-10-17 18:00 and ended at 2023-10-17 20:58 (all times are US/Pacific).
Previously affected location(s)
Sydney (australia-southeast1)
| Date | Time | Description | |
|---|---|---|---|
| | 18 Oct 2023 | 15:48 PDT | Mini Incident ReportWe apologize for the inconvenience this service disruption/outage may have caused. We would like to provide some information about this incident below. Please note, this information is based on our best knowledge at the time of posting and is subject to change as our investigation continues. If you have experienced impact outside of what is listed below, please reach out to Google Cloud Support using https://cloud.google.com/support or to Google Workspace Support using help article https://support.google.com/a/answer/1047213. (All Times US/Pacific) Incident Start: 17 October 2023 18:00 Incident End: 17 October 2023 20:58 Duration: 2 hours, 58 minutes Affected Services and Features: Google Cloud VMware Engine Regions/Zones: australia-southeast1 Description: Google Cloud VMware Engine experienced connectivity issues in australia-southeast1 for a duration of 2 hours, 58 minutes. From preliminary analysis, the root cause of the issue was the loss of multiple Virtual Private Cloud (VPC) peer circuits for the affected data center. Customer Impact:
Additional details: Google engineers brought up a backup transit link on the remaining circuit at 18:03 US/Pacific, which restored connectivity between stretch sites. Engineers then began migrating customer connections to the remaining circuit to restore access from on-premises sites. All Virtual Private Cloud (VPC) peer circuits were restored by 20:58 US/Pacific. Some customers may have experienced residual impact beyond the resolution time due to the duration of time that their stretch sites were unreachable. |
| | 17 Oct 2023 | 21:15 PDT | The issue with VMWare engine has been resolved for all affected users as of Tuesday, 2023-10-17 20:54 US/Pacific. We thank you for your patience while we worked on resolving the issue. |
| | 17 Oct 2023 | 20:06 PDT | Summary: Google Cloud VMWare engine is experiencing network link issues Description: The impact for Stretch Clusters is now mitigated. Our engineering team is continuing to work on mitigation for the rest of VMWare engine traffic in the region. The mitigation is expected to complete by Tuesday, 2023-10-17 21:15 US/Pacific. We will provide more information by Tuesday, 2023-10-17 21:30 US/Pacific. Diagnosis: - Affected customers may experience issues with Apps responding.
Workaround: None at this time. |
| | 17 Oct 2023 | 19:17 PDT | Summary: Google Cloud VMWare engine is experiencing network link issues Description: The impact for Stretch Clusters is now mitigated. Our engineering team is continuing to work on mitigation for the rest of VMWare engine traffic in the region. The mitigation is expected to complete by Tuesday, 2023-10-17 20:15 US/Pacific. We will provide more information by Tuesday, 2023-10-17 20:30 US/Pacific. Diagnosis:
Workaround: None at this time. |
| | 17 Oct 2023 | 18:56 PDT | Summary: Google Cloud VMWare engine is experiencing network link issues Description: Mitigation work is currently underway by our engineering team. We do not have an ETA for mitigation at this point. We will provide more information by Tuesday, 2023-10-17 19:30 US/Pacific. Diagnosis:
Workaround: None at this time. |
- All times are US/Pacific